OverviewThis dissertation, Characterization of a New Commercial Radiation Detector: Synthetic Single Crystal Diamond Detector by Siu-kee, Hui, 許兆基, was obtained from The University of Hong Kong (Pokfulam, Hong Kong) and is being sold pursuant to Creative Commons: Attribution 3.0 Hong Kong License. The content of this dissertation has not been altered in any way. We have altered the formatting in order to facilitate the ease of printing and reading of the dissertation. All rights not granted by the above license are retained by the author. Abstract: Diamond has long been the material of interest for radiotherapy dosimetry due to its high sensitivity, radiation hardness and near tissue equivalency. However natural diamond detector has not become a popular choice because of variability among detectors, high cost and response dependence on dose rate. The recent success in synthesizing single crystal diamond has reignited the interest. Synthetic diamond is highly reproducible in purity and electrical properties, combined with small size, it is a suitable candidate for small field dosimetry. A newly available synthetic single crystal diamond detector is being studied to determine the basic dosimetric characteristic and applicability in small field dosimetry. A series of measurements were made in comparison with a 0.125c.c ionization chamber, and two diode detectors. Response of the diamond detector is independent on dose, dose rate and energy. The output factors of small fields determined by the diamond detector is lower than that of the diode detectors and higher than that of the ionization chamber which are known to over response and under response respectively. In percentage depth dose and beam profile measurements, the diamond detector performs similarly with the two diode detectors. It is found that the diamond detector is suitable for small field relative dosimetry. Further investigation is required to study the spatial resolution of the diamond detector in different measurement geometry and the suitability in determining percentage depth dose in the buildup region. DOI: 10.5353/th_b5303912 Subjects: Radiation dosimetry Full Product DetailsAuthor: Siu-Kee Hui , 許兆基Publisher: Open Dissertation Press Imprint: Open Dissertation Press Dimensions: Width: 21.60cm , Height: 0.80cm , Length: 27.90cm Weight: 0.540kg ISBN: 9781361351116ISBN 10: 136135111 Publication Date: 27 January 2017 Audience: General/trade , General Format: Hardback Publisher's Status: Active Availability: Temporarily unavailable The supplier advises that this item is temporarily unavailable. It will be ordered for you and placed on backorder. Once it does come back in stock, we will ship it out to you. Table of ContentsReviewsAuthor InformationTab Content 6Author Website:Countries AvailableAll regions |